Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE > BUILDING WIRE / NM
Sort By:
1 2 3 ... 5
Romex SIMpull 14/2NM-WGX1000 Type NM-B Building Wire
Southwire 14/2NM-WGX1000 Sheathed Cable, 14 AWG Wire, 2 -Conductor, 1000 ft L, Copper Conductor, PVC Insulation
Our Price: $0.39

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. more info
Romex SIMpull 12/2NM-WGX1000 Type NM-B Building Wire
Southwire 12/2NM-WGX1000 Sheathed Cable, 12 AWG Wire, 2 -Conductor, 1000 ft L, Copper Conductor, PVC Insulation
Our Price: $0.59

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. more info
Romex SIMpull 28827472 Type NM-B Building Wire
Southwire 28827472 Sheathed Cable, 14 AWG Wire, 2 -Conductor, 450 ft L, Copper Conductor, PVC Insulation
Our Price: $0.69

Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. more info
Romex SIMpull 28828272 Type NM-B Building Wire
Southwire 28828272 Sheathed Cable, 12 AWG Wire, 2 -Conductor, 400 ft L, Copper Conductor, PVC Insulation
Our Price: $0.89

Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. more info
Romex SIMpull 12/3NM-WGX1000FT Type NM-B Building Wire
Southwire 12/3NM-WGX1000FT Sheathed Cable, 12 AWG Wire, 3 -Conductor, 1000 ft L, Copper Conductor, PVC Insulation
Our Price: $0.99

Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. 3 conductors, 1000 ft spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. more info
Romex SIMpull 12/2NMW/GX500FT Type NM-B Building Wire
Southwire 12/2NMW/GX500FT Sheathed Cable, 12 AWG Wire, 2 -Conductor, 500 ft L, Copper Conductor, PVC Insulation
Our Price: $0.99

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. more info
Romex SIMpull 10/2NM-WGX1000 Type NM-B Building Wire
Southwire 10/2NM-WGX1000 Sheathed Cable, 10 AWG Wire, 2 -Conductor, 1000 ft L, Copper Conductor, PVC Insulation
Our Price: $1.19

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. more info
Romex SIMpull 63947672 Type NM-B Building Wire
Southwire 63947672 Sheathed Cable, Yellow Sheath, 12 AWG Wire, 3-Conductor, 250 ft L, PVC Insulation
Our Price: $1.39

Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. more info
Romex SIMpull 10/3NM-WGX1000FT Type NM-B Building Wire
Southwire 10/3NM-WGX1000FT Sheathed Cable, 10 AWG Wire, 3 -Conductor, 1000 ft L, Copper Conductor, PVC Insulation
Our Price: $1.69

Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. 3 conductors, 1000 ft spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. more info
Romex SIMpull 8/2NM-WGX125 Type NM-B Building Wire
Southwire 8/2NM-WGX125 Sheathed Cable, 8 AWG Wire, 2 -Conductor, 125 ft L, Copper Conductor, PVC Insulation
Our Price: $1.79

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. more info
   
 
1 2 3 ... 5